Sign In | Join Free | My himfr.com
Home > Mould Release Agent >

Mould Release Agent For Electric Insulator Moulds With APG Process

jiangte insulation composite
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Mould Release Agent For Electric Insulator Moulds With APG Process from wholesalers
     
    Buy cheap Mould Release Agent For Electric Insulator Moulds With APG Process from wholesalers
    • Buy cheap Mould Release Agent For Electric Insulator Moulds With APG Process from wholesalers
    • Buy cheap Mould Release Agent For Electric Insulator Moulds With APG Process from wholesalers
    • Buy cheap Mould Release Agent For Electric Insulator Moulds With APG Process from wholesalers
    • Buy cheap Mould Release Agent For Electric Insulator Moulds With APG Process from wholesalers
    • Buy cheap Mould Release Agent For Electric Insulator Moulds With APG Process from wholesalers

    Mould Release Agent For Electric Insulator Moulds With APG Process

    Ask Lasest Price
    Brand Name : JT
    Model Number : JT616
    Certification : ISO
    Price : negotiable
    Supply Ability : 25 tons/ week
    • Product Details
    • Company Profile

    Mould Release Agent For Electric Insulator Moulds With APG Process

    Mould Cleaning Agent for High voltage power APG and mixer for pouring equipment


    MSDS:


    1. IDENTIFICATION

    Commodity name: JT6300 cleaning liquid

    Recommended use of the chemical and restrictions on use: For industry use only.

    Company Name: HUBEI JIANGTE INSULATION COMPOSITE CO., LTD.

    Add: No.219, Zhanghua Rd(N), EDA of Qianjiang City, Hubei Province, China

    Tel:+86-728-6201068

    Fax:+86-728-6202066

    Zip code:433132


    2. HAZARDS IDENTIFICATION


    HEALTH HAZARDS

    Irritating to skin

    Harmful: may cause lung damage if swallowed

    Vapours may cause drowsiness and dizziness


    ENVIRONMENTAL HAZARDS

    Toxic to aquatic organisms, may cause long term adverse effects in the aquatic environment


    PHYSICAL AND CHEMICAL HAZARDS/FIRE AND EXPLOSION HAZARDS

    Extreme hazard. Leaks of gas or spills of liquid can readily form flammable mixtures at temperatures at or above the flash point

    Static discharge. Product can accumulate static charges which can cause an incendiary electrical discharge


    3. COMPOSITON INFORMATION ON INGREDIENT

    Chemical NameCAS NoContent(%)
    Octane and Isomers64741-66-860-75

    4. FIRST AID MEASURES

    INHALATION

    - Using proper respiratory protection, immediately remove the affected victim from exposure. Administer artificial respiration if breathing is stopped. Keep at rest. Call for prompt medical attention.


    SKIN CONTACT

    - Flush with large amounts of water; use soap if available

    - Remove grossly contaminated clothing, including shoes, and launder before reuse


    EYE CONTACT:

    Flush eyes with large amounts of water until irritation subsides. If irritation persists, get medical attention


    INGESTION:

    -If swallowed, do not induce vomiting. Keep at rest. Get pro,pt medical attention.


    5. FIRE-FIGHTING MEASURES


    FIRE FIGHTING PROCEDURES:

    -Use water spray to cool fire exposed surfaces and to protect personnel. Shut off” Fuel” to fire. If a leak or spill has not ignited, use water spray to disperse the vapors and to protect men attempting to stop a leak

    -Either allow fire to burn under controlled conditions or extinguish with foam or dry chemical.

    Try to cover liquid spills with foam.


    SPECIAL FIRE PRECAUTIONS:

    -Avoid spraying water directly into storage containers due to danger of boilver

    -See also Section 4” FIRST AID MEASURES” as well as Section 10 “ STABILITY AND REACTIVITY”


    HAZARDOUS CPMBUSTION PRODUCTS:

    No unusual


    6. ACCIDENTAL RELEASE MEASURES

    LAND SPILL:

    -Eliminate sources of ignition. Warn occupants of downwind areas of fire and explosion hazard. Prevent liquid from entering sewers, watercourses, or low areas.

    -Keep public away, Shut off source if possible to do so without hazard.

    Advise authorities if substance has entered a watercourse or sewer or has contaminated soil or vegetation. Take measures to minimize the effect on the ground water.

    - Contain spilled liquid with sand or earth

    -Recover by pumping( use an explosion proof or hand pump) or with a suitable absorbent. If liquid is too viscous for pumping, scrape up with shovels or pails and place in suitable containers for recycle or disposal.

    -Consult an expert on disposal of recovered material and ensure conformity to local disposal regulations.

    - See Section 4” FIRST AID MEASURES” as well as Section 10” STABILITY AND REACTIVITY”


    7. HANDLING AND STORAGE

    STORAGE TEMPERATURE(Degc): Ambient

    TRANSPORT TEMPERATURE(DegC): Ambient

    LOADING/UNLOADING TEMPERATURE(DegC):

    VISCOSITY(cSt): 0.90


    STORAGE/TRANSPORT PRESSURE(kPa): Atmospheric

    ELECTROSTATIC ACCUMULATION HAZARD

    Yes, use proper grounding procedure


    USUAL SHIPPING CONTAINERS:

    Tankers, rail wagons, tank trucks, drums


    MATERIALS AND COATINGS SUITABLE:

    Carbon Steel

    Stainless Steel

    Polyethylene

    Polypropylene

    Polyester

    Teflon


    MATERIALS AND COATINGS UNSUITABLE:

    Natural Rubber

    Butyl Rubber

    EPDM

    Polystyrene


    Compatibility with plastic materials can vary; we therefore recommend that compatibility is tested prior to use.


    STORAGE/HANDING, GENRAL NOTES

    -Keep container closed. Handle containers with care. Open slowly in order to control possible pressure release. Store in a cool, well-ventilated place away from incompatible materials.

    -Do not handle, store or open near an open flame, sources of heat or sources of ignition. Protect material from direct sunlight.

    -Material will accumulate static charges which may cause an electrical spark(ignition source). Use proper bonding and/ or grounding procedures.

    -Do not pressurize, cut, heat, or weld containers. Empty product containers may contain product residue. Do not reuse empty containers without commercial cleaning or reconditioning.


    ADDITIONAL WARNINGS

    Containers remains hazardous when empty. Continue to observe all precautions.


    8. EXPOSURE CONTROLS/PERSONAL PROTECTION


    ENGINEERING CONTROLMEASURES/VENTILATION

    The use of mechanical dilution ventilation is recommended whenever this product is used in a confined space, is heated above ambient temperatures or otherwise to maintain ambient concentration below the recommended threshold exposure limits. Use explosion-proof ventilation equipment.


    OCCUPATIONAL EXPOSURE LIMITS

    Exxonmobil recommends, for total hydrocarbons, based on composition and using the Reciprocal Calculation Procedure(RCP):


    Alkanes, C7-C10-ISO;

    TWA: 1400mg/m3(281ppm), ExxonMobil(2000).


    This product contains the following components with a recognized or recommended OEL value:


    Octane:

    TAW: 300 ppm(1400mg/m3), ACGTH(2002)


    PERSONAL PROTECTION


    GENERAL ADVICE

    The use and choice of personal protection equipment is related to the hazard of the product, the workplace, and the way the product is handled.

    In general, we recommend as a minimum safety precaution that safety glasses with side-shields and workclothes protecting arms, legs and body be used. In addition, any person visiting an area where this product is handled or processed should at least wear safety glasses with side-shields.


    SPECIAL ADICE

    Based on and limited to ExxonMobil’s experience of this product as such the following special advice is believed to provide satisfactory protection for the industrial user or handler


    RESPIRATORY PROTECTION

    Where concentrations in air may exceed the limits given in this section, it is recommend to use a half face filter mask to protect from overexposure by inhalation. Suitable filter material depends on the amount and type of chemicals being handled in the workplace, but filter material of type“A”or similar may be considered for use.


    HAND PROTECTION

    When handling this product, it is recommended to wear chemical resistant gloves. The choice of suitable protective gloves depends on work conditions and what chemicals are handled, but we have positive experience with gloves made of Nitrile. Gloves should be replaced immediately if sign of degradation is observed.


    EYE PROTECTION

    See general advice


    SKIN/BODY PROTECTION

    See general advice


    SKIN/BODY PROTECTION

    See general advice


    9. PHYSICAL AND CHEMICAL PROPERTIES

    These are indicative values only. Please refer also to the product specification sheet.


    9.1 General information

    PHYSICAL STATE: liquid

    FORM/COLOUR: Clear colourless liquid

    ODOR: Isoparaffinic hydrocarbon odour

    Mould Release Agent For Electric Insulator Moulds With APG Process


    FREEZ/MELT/POINT: -62.78 DegC ASTM D97 (Pour Point)

    BOILING POINT RANGE: between 115 and 138.89 DegC ASTM D1078

    VAPOR PRESSURE( 20 degC): 2.15 Kpa Estimate

    DENSITY(101.3 kPa/air=1): >4.10

    VISCOSITY (25 DegC): 0.85 mm2/s ASTM

    EVAPORATION RATE(n-Bu Acetate=1): 1.850


    9.2 Health, Safety& Environmental Information

    Flashpont(TCC ASTM D56): 7 DegC Typical

    AUTOIGNITION TEMPERATURE: 395 DegC

    EXPLOSIVE LIMITS( in air):

    Between 0.9 abd 6.2 Vol%

    SOLUBILITY IN WATER(20 DegC): <0.10 Wt%


    9.3 Other Information

    MOLECULAR WEIGHT: 118 Average

    COEFF OF THERMAL EXPANSION(Liq): 0.00085 Vol/vol/deg C

    IS MATERIAL HYGROSCOPIC: No


    10. STABILITY AND REACTIVITY

    HAZARDOUS POLYMERIZATION? No

    CONDITIONS TO AVOID POLYMERIZATION:

    Not Applicable


    STABILITY: Stable

    CONDITIONS TO AVOID INSTABILITY:

    Not Applicable.


    MATERIALS AND CONDITIONS TO AVOID(INCOMPATIBILITY)

    Strong oxidizing agents


    HAZARDOUS DECOMPOSITION PRODUCTS:

    None


    11. TOXICOLOGICAL INFORMATION


    ACUTE:

    INHALATION:

    -High vapor/aerosol concentrations(greater than approximately 700ppm, attainable at elevated temperatures well above ambient) are irritating to the eyes and the respiratory tract, and may cause headaches, dizziness, anaesthesia, drowsiness,unconsciousness, and other central nervous system effects, including death.


    SKIN CONTACT:

    -Frequent or prolonged contact may defat and dry the skin, leading to discomfort and dermatitis.

    -Low order of toxicity

    -

    EYE CONTACT:

    -Will cause eye discomfort, but will not injure eye tissue


    INGESTION:

    -Small amounts of liquid aspirated into the respiratory system during ingestion or from vomiting may cause bronchopnbeumonia or pulmonary edema.

    - Minimal toxicity


    Additional information is available on special request


    12. ECOLOGICALINFORMATION


    ENVIRONMENTAL MOBILITY

    This product is highly volatile and will rapidly evaporate to the air if released to the water


    ENVIRONMENTAL DEGRADABILITY

    Based upon data for a smilar component or preparation, or estimated data.

    This substance is expected to biodegrade at a moderate rate and be “inherently” biodegradable according to OECD guidelines.


    ECOTOXICITY AND BIOACCUMULATION

    Expected to be toxic to aquatic organisms

    Long term adverse effects to aquatic organisms are possible if continuous exposure is maintained.


    13. DISPOSAL CONSIDERATIONS

    The following advice only applies to the product as supplied.

    Combination with other materials may well indicate another route of disposal. If in doubt, contact the local ExxonMobil affilite or local Authorities.


    Empty packaging should be taken for recycling, recovery or disposal through a suitable qualified or licensed contractor.


    Care should in any case be taken into ensure compliance with national and local regulations.


    This product is NOT suitable for disposal by either landfill or via municipal sewers, drains, natural streams or rivers.

    This product is ashless and can be burned directly in appropriate equipment


    14. TRANSPORT INFORMATION

    LAND

    CLASS: 3 PG:II UN NUMBER:3295

    HAZCHEM CODE: 3WE SUBSIDIARY RISK:

    TRANSPORT DOCUMENT NAME:

    HYDROCARBONS,LIQUID, N.O.S.(Isooctanes & Isononanes), CLAS3, UN 3295, PG II,( 7 Deg C )


    AIR(ICAO/IATA)

    CLASS: 3 PG: II UN NUMBER: 3295

    PROPER SHIPPING NAME:

    HYDRICARBONS, LIQUID, N.O.S.(Isooctanes & Isononanes)


    15. REGULATORY INFORMATION

    CLASSIFICATION AND LABELLING ACCORDING TO EC DIRECTIVES

    CLASSIFICATION/SYMBOL: HIGHLY FLAMMABLE/F

    CLASSFICATION/SYMBOL:DANGEROUS FOR THE ENVIRONMENT


    GOVERING DIRECTIVE:

    Dangerous Substance Directive 67/548/EC, as modified.


    NATURE OF SPECIAL RISK

    R11 Highly flammable

    R38 Irritating to skin

    R51/53 Toxic to aquatic organisms, may cause long term adverse effects in the aquatic environment

    R65 Harmful: may cause lung damage if swallowed

    R67 Vapour may cause drowsiness and dizziness


    SAFETY ADVICE

    S09 Keep container in a well ventilated place

    S16 Keep away from sources of ignition-No smoking

    S23 Do not breathe gas/fumes/vapour/spray

    S24 Avoid contact with skin

    S33 Take precautionary measures against static discharges

    S43A In case of fire use sand, earth,chemical powder or foam

    S57 Use appropriate container to avoid environmental contamination

    S60 This material and/or its container must be disposed of as hazardous waste

    S62 If swallowed, do not induce vomiting: seek medical advice immediately and show this container or label


    16. OTHER INFORMATION

    A. Reference

    - The information contained herein is believed to be accurate. It is provided independently of any sale of the product for purpose of hazard communication. It is not intended to constitute performance information concerning the product. No express warranty, or implied warranty of merchantability or fitness for a particular purpose is made with respect to the product or the information contained herein.


    B. Last date revised

    - 2017-01-10


    C. Other

    - This SDS is prepared according to the Globally Harmonized System (GHS).

    TDS:

    Performance parameters:

    AspectUnitValue
    colour and lustreTransparent liquid
    ViscositymPa.s15
    Flash point65
    Spread rate20-25
    Densityg/mm30.90-0.92


    Mould Release Agent For Electric Insulator Moulds With APG ProcessMould Release Agent For Electric Insulator Moulds With APG Process

    Product Description:

    JT 6101 Organic Silicon Mould Release agent


    Features:

    Good release effect

    high stability

    No reaction with the casting material

    Not corrode the mold

    Environment protection and without pollution


    Process:

    1. Remove grease and wax thoroughly with solvent to ensure the mould cavity clean and dry

    2. For the new mould, initial using need to spray for 3-4times(After the solvent evaporation and then spray brush again),after that one mould to spray one time or several moulds to spray one time(several moulds to spray one time: normally paint one time after the mould poured 2~10 times)

    3. When a thin coating can be formed on the surface of the mold cavity by the method of spraying or brushing, then it is ok


    Packing:

    5KG/ pot,20kg/drum


    Storage:

    Products need to be stored in a dry and ventilated environment with 18-40℃, and the shelf life is 1 year


    Mould Release Agent For Electric Insulator Moulds With APG ProcessMould Release Agent For Electric Insulator Moulds With APG Process


    Hubei Plant and Guangdong plant:

    Mould Release Agent For Electric Insulator Moulds With APG Process


    ISO certificate:

    Mould Release Agent For Electric Insulator Moulds With APG ProcessMould Release Agent For Electric Insulator Moulds With APG Process


    Part of our customers:

    Mould Release Agent For Electric Insulator Moulds With APG Process

    Mould Release Agent For Electric Insulator Moulds With APG Process


    FAQ:

    1. We’re using Huntsman epoxy resin, can I use JiangTe resin?

    Yes,ours are equivalent to Huntsman. Please tell the number of Huntsman you’re using, we’ll offer the one matching.

    2. What’s the pot life?

    Pre-filled resin is one year; Pure resin is 2-3 years.

    3. We’re just starting producing. Can you help us on the process?

    No problem, we’ll offer guidance and support. We have thousands of customer manufacturers in China and overseas.

    So we have good experiences.


    Quality Mould Release Agent For Electric Insulator Moulds With APG Process for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: jiangte insulation composite
    *Subject:
    *Message:
    Characters Remaining: (0/3000)